Basic Requirements for Construction Permit Application
Commercial
These requirements are to be used as a guide to assist you in completing the
application process. They do not cover every type of work.
EFFECTIVE Jan 4, 2010 there will be a
Zoning Permit Fee of $50.00 payable to “Bernards Township”
due upon submittal of any Construction Permit Application that requires Zoning
Review.
All applications
Submit completed applications for the work intended, and 2 copies of plans. (If you are submitting plans see the plan
requirements.) Exceptions to the plan requirement may include Water heaters,
Boilers, Furnaces and minor work.
A completed application will include the following forms.
- Completed Construction Permit
Application (Folder UCC form F100-1 complete sections I, II, III, IV, VI
& VII. You must also complete and sign the inside certification
section either as the agent or owner.)
- Completed Technical Sections
for work being performed ie: Building F110, Electrical F120, Plumbing F130
or Fire Protection F140 or Counter Form. A NJ Licensed Plumber or
Electrician must sign and seal the appropriate technical section. A
penalty of $2000 will be issued for false application or performing work
without a license.
Each technical section has specific information, which needs to be submitted
for each type of work that is being applied for. IE: Contractor information,
alteration costs, number of fixtures, smoke detectors, etc. These forms must be
signed and or sealed as appropriate.
Please note alteration costs on the Building
Subcode Technical Section are considered the estimated cost of the work for
which the permit is sought, including but not limited to building construction,
on-site construction, and all integral equipment, built in furnishings and
equipment. If both an addition and alteration are being applied for then you
must break down the cost of the addition and alteration as indicated on the
form.
- Other documentation may need
to be submitted for specific types of work. Consult a technical assistant
for more information I.e.: Sewer permits, Board of Health, Tree removal
permits.
Applications for new buildings, additions, accessory structures, tenant
fit-outs, and signs.
Submit completed applications as described above and include payment for
Zoning Permit Fees of $50.00 payable to “Bernards Township”
and 3 copies of a property survey
indicating the new addition or structure on the property. We will forward the
application to Engineering for prior approvals as necessary.
The application folder UCC form F100-1 and the Building Subcode Technical
Section UCC form F110 must indicate the CUBIC VOLUME and SQUARE FOOTAGE of the
building as required on the forms. Use the following formulas to calculate
CUBIC VOLUME and SQUARE FOOTAGE.
CUBIC VOLUME = Length X Width X Height = cu. ft.
SQUARE FOOTAGE = Length X Width = sq. ft.
Minimum plan submittal requirements
Plans must be signed and sealed by a NJ licensed architect or engineer.
Plans are to reflect professional quality worthy of the Architectural
Profession. Questionable quality may be referred to the State Board of
Architects for review.
Items to be indicated on Construction Plans:
- Use Group of tenant space and
the use of the other adjacent tenant spaces.
- Gross Floor Area of tenant
space.
- Occupancy Load of tenant space.
- Key locater plan of tenant
space within building level.
- Exiting plan of tenant space
to nearest approved exit, show location of exit signs.
- Cross-section of all proposed
walls and partitions.
- Tenant space floor plan, show
unit number.
- Show all tenant separation
walls, the required Fire Resistance rating of that wall and the
appropriate U.L. Design number.
- Include a store shelving or
fixture plan. Indicate net clear aisle width of all proposed aisles and
corridors.
- Show any proposed plumbing
fixture plan and the appropriate riser diagram.
- Show single line electrical
circuit plan, switch, outlet and fixture plan, sub-panel location,
amperage of sub-panel, panel labeling plan of each circuit and reflective
ceiling plan.
- List all dimensions of scaled
plan.
- Show location of all doors
& windows.
- Identify all glass panels by
others, which are to have safety glazing.
- Show H.V.A.C. duct diffuser
plan, determine to H.V.A.C. airflow requirements for tenant space, and
indicate minimum CFM’s.
- Provide product spec sheets
where applicable.
- Provide all other pertinent
information and data to satisfy code requirements.
- Indicate all required
accessibility as per CABO ANSI A117.1.